3. Main Technical Specifications
Type | Value | Unit | Remarks | |
---|---|---|---|---|
Power Input | 220 ± 10% | VAC | 50Hz/60Hz AC mains | |
Maximum Output Voltage | ±20.0 | kV | ||
Output Current | 0-4.0 | mA | Derating required for long-term use | |
Output Power | 80 | W | Derating recommended for long-term use | |
Adjustment Method | Fiber optic 232 module | - | computer control, manual control | |
Remote control | fiber optic isolation | - | ||
Output Ripple | 0.03 | % | full scale VRMS | |
Voltage Accuracy | ±0.05 | % | ||
Adjustment Resolution | ±0.02 | % | ||
Input Adjustment Rate | ±0.01 | % |